Visible Spectro Photometer |
| |
|
 |
| Single Beam Visible Spectro Photometer |
Double Beam Visible Spectrophoto Meter |
| Spectrophoto Meter CL-310 |
| Wave length |
| Range |
340 to 990 nm |
| Accuracy |
± 1 nm |
| Read out |
3½ digit LED, 1 nm step |
| Bandwidth |
5.0 nm |
| Photometric |
| Range |
0 to 1.999 ABS |
| Grating |
600 lines /mm |
| Source |
Tungsten Halogen Lamp 12V, 50W |
| Detector |
Silicon Photo diode |
| Measuring mode |
%T, ABS, Conc, K |
| K factor range |
0.0 to 9999 |
| Concentration Range |
0 to Double ABS |
|
 |
| |
| Spectrophoto Meter CL-320 |
| Wave length |
| Range |
340 to 960 nm |
| Accuracy |
± 1 nm |
| Read out |
5 nm step, Dial |
| Bandwidth |
5.0 nm |
| Photometric |
| Range |
0 to 1.999 ABS |
| Grating |
600 lines /mm |
| Source |
Tungsten Halogen Lamp 12V, 50W |
| Detector |
Silicon Photo diode |
| Measuring mode |
%T, ABS, Conc, K |
| K factor range |
0.0 to 9999 |
| Concentration Range |
0 to Double ABS |
|
 |
| |
| Spectrophoto Meter CL-330 |
| Wave length |
| Range |
340 to 990 nm |
| Accuracy |
± 1 nm |
| Read out |
3½ digit LED, 1 nm step |
| Bandwidth |
5.0 nm |
| Photometric |
| Range |
-0.3 to 2.500 ABS |
| Grating |
600 lines /mm |
| Source |
Tungsten Halogen Lamp 12V, 50W |
| Detector |
Silicon Photo diode |
| Measuring mode |
%T, ABS, Conc, K |
| K factor range |
0.0 to 9999 |
| Concentration Range |
0 to 9999 |
|
 |
| |
| Spectrophoto Meter CL-335 |
| Wave length |
| Range |
340 to 990 nm |
| Accuracy |
± 1 nm |
| Read out |
3½ digit LED, 1 nm step |
| Bandwidth |
5.0 nm |
| Photometric |
| Range |
-0.3 to 2.500 ABS |
| Grating |
600 lines /mm |
| Source |
Tungsten Halogen Lamp 12V, 50W |
| Detector |
Silicon Photo diode |
| Measuring mode |
%T, ABS, Conc, Scan |
| K factor range |
0.0 to 9999 |
| Concentration range |
0 to 9999 |
|
 |
| |
| Spectrophoto Meter CL-340 |
| Wave length |
| Range |
340 to 960 nm |
| Accuracy |
± 1 nm |
| Read out |
5 nm step, Dial |
| Bandwidth |
5.0 nm |
| Photometric |
| Range |
-0.3 to 2.500 ABS |
| Grating |
600 lines /mm |
| Source |
Tungsten Halogen Lamp 12V, 50W |
| Detector |
Silicon Photo diode |
| Measuring mode |
%T, ABS, Conc, K |
| K factor range |
0.0 to 9999 |
| Concentration Range |
0 to 9999 |
|
 |
| |
| Spectro Photometer CL-350 |
| Wave length |
| Range |
340 to 990 nm |
| Wave length resolution |
1.0 nm |
| Accuracy |
± 1 nm |
| Read out |
20 x 2 LCD |
| Bandwidth |
5.0 nm |
| Photometric |
| Range |
-0.3 to 2.000 Abs |
| Accuracy |
+0.005 Abs at 1.0A |
| Grating |
600 lines /mm |
| Source |
Tungsten Halogen Lamp 12V, 50W |
| Detector |
Silicon Photo diode |
| Measuring mode |
%T, ABS, Conc, Scan, Time Scan |
| Concentration range |
0 to 9999 with floating decimal pt. |
| Sample holder |
2 position manual cuvetter holder |
| Printer port |
Dot matrix compatible |
| Optional |
RS232 Software |
| |
|
|
 |
| |
| Spectro Photometer CL-351 |
| Wave length |
| Range |
340 to 990 nm |
| Wave length resolution |
1.0 nm |
| Accuracy |
± 1 nm |
| Read out |
20 x 2 LCD |
| Bandwidth |
5.0 nm |
| Photometric |
| Range |
-0.3 to 2.000 Abs |
| Accuracy |
+0.005 Abs at 1.0A |
| Grating |
600 lines /mm |
| Source |
Tungsten Halogen Lamp 12V, 50W |
| Detector |
Silicon Photo diode |
| Measuring mode |
%T, ABS, Conc, Scan, Time Scan |
| Concentration range |
0 to 9999 with floating decimal pt. |
| Sample holder |
4 position auto cuvetter holder |
| Printer port |
Dot matrix compatible |
| Optional |
RS232 Software |
| |
|
|
 |
| |
| Spectro Photometer CL-352 |
| Wave length |
| Range |
340 to 990 nm |
| Wave length resolution |
0.1 nm |
| Accuracy |
± 1 nm |
| Read out |
20 x 2 LCD |
| Bandwidth |
5.0 nm |
| Photometric |
| Range |
-0.3 to 2.000 Abs |
| Accuracy |
+0.005 Abs at 1.0A |
| Grating |
600 lines /mm |
| Source |
Tungsten Halogen Lamp 12V, 50W |
| Detector |
Silicon Photo diode |
| Measuring mode |
%T, ABS, Conc, Scan, Time Scan |
| Concentration range |
0 to 9999 with floating decimal pt. |
| Sample holder |
2 position auto cuvetter holder |
| Printer port |
Dot matrix compatible |
| Optional |
RS232 Software |
| |
|
|
 |
| |
| Spectro Photometer CL-353 |
| Wave length |
| Range |
340 to 990 nm |
| Wave length resolution |
0.1 nm |
| Accuracy |
± 1 nm |
| Read out |
20 x 2 LCD |
| Bandwidth |
5.0 nm |
| Photometric |
| Range |
-0.3 to 2.000 Abs |
| Accuracy |
+0.005 Abs at 1.0A |
| Grating |
600 lines /mm |
| Source |
Tungsten Halogen Lamp 12V, 50W |
| Detector |
Silicon Photo diode |
| Measuring mode |
%T, ABS, Conc, Scan, Time Scan |
| Concentration range |
0 to 9999 with floating decimal pt. |
| Sample holder |
4 position auto cuvetter holder |
| Printer port |
Dot matrix compatible |
| Optional |
RS232 Software |
| |
|
|
 |
| |
|